Specification Sheet
            WB-3005, WB-3505
Horizontal Water Bath Vaporizer
        Horizontal Water Bath Vaporizer
| Type | Horizontal Water Bath LPG Vaporizer | ||
| Model Number | WB-3005 | WB-3505 | |
| Capacity | gph | 3005 | 3505 | 
| kg/h | 5766 | 6726 | |
| MMBTU/h | 277 | 323 | |
| kW | 81180 | 94660 | |
| Water Tank Capacity | 
 2035 Gallons (7.71 m3) to Fill Plug  | 
||
| Burner Type | 
 Forced Draft Power Burner,  8-inch Maxon Tube-O-Therm or similar;   | 
||
| Burner Capacity | MMBTU/h | 3.750 | 4.200 | 
| kW | 1099 | 1231 | |
| Design Temperature | 650 °F (343 °C) | ||
| Design Pressure | 250 PSIG (17.2 bar) | ||
| Manufactured Construction | Vaporizing Tube Conforms to ASME Boiler &  Pressure Vessel Code, Section VIII, Division I. Conforms to latest edition  of NFPA #58.  Power type Burner; Electronic Flame Safeguard; Electronic System Controls with Siemens or Allen-Bradley PLC and Operator Interface with color LCD display and touch screen. First-Outage Monitor (Alarm History with date and time stamp) and graphic trend recording.  | 
||
| Approvals | Factory Mutual (FM) or Industrial Risk Insurers  (IRI). Canadian Standards Association (CSA). Optional European CE Approval including PED, ATEX, and all other applicable Directives.  | 
||
| Standard Safety Features | 
  | 
||
| Liquid Inlet Connection | 2" 300# Raised Face ANSI Flange (Optional DN50 PN25 DIN Flange) | ||
| Liquid Inlet Valve | 250 psi Flanged Direct-Acting Solenoid Valve; with Check Valve Bypass; Ball Valve for Manual Shutoff. | ||
| Vapor Outlet | 4" 300# Raised Face ANSI Flange (Optional DN100 PN25 DIN Flange) | ||
| PLC and Electronic Operator Interface | 
  | 
||
| Electrical Requirement | 
 380/400/480VAC 50/60Hz; 25A  Circuit; 3-Phase;  | 
||
| Circuit Protection | Automatic Circuit Breakers with Manual Reset for all AC and DC Circuits; Main Breaker/Disconnect. | ||
| Design Criteria, Vaporizer | Designed and manufactured to comply with the latest edition of NFPA Pamphlet 58; FM approved. European CE Mark available. | ||
| Design Criteria, LPG Heat Exchanger | Designed and manufactured in compliance with ASME Boiler and Pressure Vessel Code Section VIII, Division 1. ASME U-Stamp  available.  CE-marked vaporizers comply with European PED.  | 
||
| Design Criteria, Control Panel | General-purpose wiring, compliant with National Electric Code (NEC; NFPA #70). UL-508A available. CE-marked vaporizers comply with all applicable European Directives. | ||
| Mechanical Construction, Skid Base  | 
1/4-inch (6.35mm) Steel Deck Plate on all-welded 6-inch (150mm) Tubular Frame with Cross-Members; Lifting Lugs; mechanically cleaned, primed, and painted (AES Blue, RAL 5015). | ||
| Mechanical Construction, Bath Box  | 
1/4-inch (6.35mm) all-welded steel walls with internal stiffeners and supports for LPG Heat Exchanger. | ||
| Mechanical Construction, Water Circulating Pump  | 
Wet-Cartridge Type Hot-Water Circulator installed inside Vaporizer Control Room. Diffuser in Water Bath. | ||
| Mechanical Construction, Insulation  | 
Mineral Fiber insulation with Aluminum backing on side walls, top plate, and front and rear wall. | ||
| Mechanical Construction, Bath Box Cover  | 
16-gauge (1.5mm) Sheet Metal Panels, powder-coated (gray RAL 9002). | ||
| Mechanical Construction, Control Room  | 
12-gauge (2.7mm) Sheet Metal, primed and painted (AES Blue, RAL 5015); lockable door; louvers, window insert. | ||
| Mechanical Construction, Dimensions  | 
 80 x 240 x 112 (inches; W x  L x H)  | 
||
| Mechanical Construction, Shipping Weight  | 
 17500 lbs  | 
||
| Catalog Drawing | Click here for Catalog Drawing (Page 8 of Brochure) | ||