Alternate Energy Systems, Inc.

LPG Vaporizers - LP/Air Blenders - Gas/Gas Blenders - NatGas Backup Systems - PeakShaving Systems


Price List
March 2016

Accessories for LPG Systems
Liquid Transfer Pumps
AEP-Series
  

Return to Main Price List Page

Download complete Price List as PDF file


Pump System Features

  • Capacities from 5 gpm to 150+ gpm
  • Direct-Drive Pumps up to 26 gpm
  • Belt-Driven Pumps 29 gpm and above
  • Skid-mounted
  • Primed and Painted
  • Inlet Strainer
  • Flexible Inlet/Outlet Connections
  • All-welded piping
  • Backpressure Regulator
  • Summer-Bypass
  • Liquid-filled Pressure Gauges
  • Single-Pump Systems
  • Duplex-Pump Systems
  • Blackmer Pumps
  • Corken Pumps
  • US Voltages
  • International Voltages
  • Ex-proof Motors
    Class I, Div. 1, Group D [Flame-Proof]

 

 

Quick-Select Chart for
AES Vaporizers / AES Pumps

Pump Selection Charts:

LPG Transfer Pumps, as the name implies, are used to transfer liquid LPG from the storage tanks to the vaporizer. In systems with venturi LPG/air mixing systems, they are also responsible for maintaining the pressure needed for optimum and efficient function of the venturi mixers.

AES uses pumps from the two leading manufacturers, Blackmer and Corken. All pumps are of "positive displacement" design and use rotary vane pumps with a built-in over-pressure relief valve, designed for continuous use with high reliability.

All pumps are mounted on steel skids, and are primed and painted. They are equipped with constant pressure regulator, strainer, isolation valves, summer bypass loops, liquid filled pressure gauges, and other components that are required for safe operation.

All systems are supplied with an explosion proof motor to meet Class I, Div. 1, Group D [Flame-Proof] requirements, and are available for 60Hz service or for 50Hz service and for various voltages. Smaller pumps are for single phase service. Larger pumps are for 3-phase service and require magnetic motor starters.

When sizing a pump system, the nominal pump capacity should be approximately twice the nominal capacity of the LP or LP/Air system. Nominal pump capacities may vary with type of LPG, ambient conditions, available electric service, required discharge pressure, and other factors.

Blackmer pumps up to model AEP-12B, and Corken pumps up to model AEP-18C, are direct-drive pumps (electric motor directly coupled to pump). Larger pumps are belt-driven.

The purpose of Duplex Pump Systems is to provide maximum redundancy. They are therefore manufactured as individual pumps that only share a common skid. All bypass and isolation valves exist in duplicate and allow using the pumps in any combination: Pump 1, Pump 2, or Pump 1 and Pump 2 together. Each pump can be completely isolated so that maintenance and repair work on this pump does not affect the other pump, or the system availability.

Magnetic motor starters can be supplied either as separate components, installed on the pump skid, or integrated with the system controls. If pump systems are integrated with the vaporizer or vaporizer/blender controls, a start/stop station in an ex-proof enclosure is installed directly at the pump skid and provides local pump control.

Integrated pumps can also be equipped with an automatic start/stop function in response to the pressure in the storage tank(s). The price adder for these options is shown below (in section "Motor Starters and other Options").

 

Corken Pumps
Selection Chart
  
60Hz
 
All prices and specifications are
subject to change without notice.

Direct-Driven Belt-Driven
CF12

AEP-
05C

CF13

AEP-
07C

FF14

AEP-
11C

FF150

AEP-
18C

Z2000

AEP-
32C

Z3500

AEP-
42C

Z3500

AEP-
53C

Z3500

AEP-
68C

Z4500

AEP-
98C

Single Pump System US-$
15,617
US-$
15,935
US-$
16,769
US-$
18,711
US-$
21,618
US-$
34,123
US-$
35,651
US-$
44,339
US-$
55,645
Duplex Pump System US-$
31,548
US-$
32,191
US-$
33,875
US-$
37,797
US-$
43,669
US-$
69,981
US-$
72,017
US-$
89,567
US-$
112,405

Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar discharge)

Find "your" LPG type and the sample operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than, the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number.

   HD-5 Propane
  
Min. Temperature   0F / -18C
   ΔP  78 psi / 5.4 bar
gph  288
kg/h  558
408
790
648
1254
1080
2091
1920
3717
2520
4878
3192
6179
4056
7852
5856
11336
   HD-5 Propane
  
Min. Temperature   -40F / -40C
   ΔP  99 psi / 6.8 bar
gph  168
kg/h  325
312
604
480
929
1008
1951
1872
3624
2280
4414
3000
5807
3936
7619
5784
11197
   LPG with 50% Propane/50%Butane
  
Min. Temperature   32F / 0C
   ΔP  74 psi / 5.1 bar
gph  216
kg/h  443
312
640
504
1034
696
1428
1176
2413
1656
3398
2064
4236
2520
5171
3576
7338
  LPG with 50% Propane/50%Butane
  
Min. Temperature   15F / -10C
   ΔP  82 psi / 5.7 bar
gph  192
kg/h  394
288
591
456
936
696
1428
1176
2413
1584
3251
1992
4088
2496
5122
3552
7289
  LPG with 30% Propane/70%Butane
  
Min. Temperature   32F / 0C
   ΔP  84 psi / 5.8 bar
gph  144
kg/h  303
216
454
336
707
480
1010
792
1666
1104
2323
1128
2373
1680
3534
2376
4999
Electric Motor 220V 60Hz 220V 60Hz  or
460V 60Hz
460V 60Hz
   Motor Type Single-Phase

3-Phase
(all 3-phase motors require magnetic starters and overload protection)

   Motor Protection

Class I, Div 1, Group D  (Flame Proof)

   Motor Size [hp] 2 3 5 7.5 7.5 10 15 20 25
   Motor RPM 3450 3450 3450 3450 750 520 640 780 520
Pump Connections

All pump body connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100 and above).

   Pump Body, Inlet 1.5" 1.5" 1.5" 1.5" 2" 3" 3" 3" 4"
   Pump Body, Outlet 1" 1" 1" 1" 2" 3" 3" 3" 4"
   Pump Skid, Inlet 2"
DN50
2"
DN50
2"
DN50
2"
DN50
3"
DN80
4"
DN100
4"
DN100
4"
DN100
6"
DN150
   Pump Skid, Outlet 1"
DN25
1"
DN25
1"
DN25
1"
DN25
2"
DN50
3"
DN80
3"
DN80
3"
DN80
3"
DN80
  

Corken Pumps
Selection Chart
  
50Hz
 
All prices and specifications are
subject to change without notice.

Direct-Driven Belt-Driven
CF12

AEP-
05C

CF13

AEP-
07C

FF075

AEP-
11C

FF150

AEP-
18C

Z2000

AEP-
32C

Z3500

AEP-
42C

Z3500

AEP-
53C

Z3500

AEP-
68C

Z4500

AEP-
98C

Single Pump System (US-$)   US-$
16,620
US-$
17,991
US-$
19,363
US-$
22,304
US-$
34,956
US-$
36,498
US-$
45,408
US-$
56,717
Duplex Pump System (US-$)   US-$
33,574
US-$
36,343
US-$
39,115
US-$
45,055
US-$
70,613
US-$
73,509
US-$
91,724
US-$
114,571

Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar discharge)

Find "your" LPG type and the sample operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than, the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number.

   HD-5 Propane
  
Min. Temperature   0F / -18C
   ΔP  78 psi / 5.4 bar
n/a gph  192
kg/h  372
528
1022
864
1673
1920
3717
2520
4878
3192
6179
4056
7852
5856
11336
   HD-5 Propane
  
Min. Temperature   -40F / -40C
   ΔP  99 psi / 6.8 bar
n/a gph    72
kg/h  139
432
836
768
1487
1872
3624
2280
4414
3000
5807
3936
7619
5784
11197
   LPG with 50% Propane/50%Butane
  
Min. Temperature   32F / 0C
   ΔP  74 psi / 5.1 bar
n/a gph  192
kg/h  394
384
788
600
1231
1176
2413
1656
3398
2064
4236
2520
5171
3576
7338
  LPG with 50% Propane/50%Butane
  
Min. Temperature   15F / -10C
   ΔP  82 psi / 5.7 bar
n/a gph  168
kg/h  345
360
739
576
1182
1176
2413
1584
3251
1992
4088
2496
5122
3552
7289
  LPG with 30% Propane/70%Butane
  
Min. Temperature   32F / 0C
   ΔP  84 psi / 5.8 bar
n/a gph  120
kg/h  252
240
505
384
808
792
1666
1104
2323
1128
2373
1680
3534
2376
4999
Electric Motor 230V 50Hz 400/415V 50Hz
   Motor Type Single-Phase

3-Phase
(all 3-phase motors require magnetic starters and overload protection)

   Motor Protection

Class I, Div 1, Group D  (Flame Proof)

   Motor Size [hp] n/a 3 5 7.5 7.5 10 15 20 25
   Motor RPM n/a 2880 2880 2880 750 520 640 780 520
Pump Connections

All pump body connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100 and above).

   Pump Body, Inlet n/a 1.5" 1.5" 1.5" 2" 3" 3" 3" 4"
   Pump Body, Outlet n/a 1" 1" 1" 2" 3" 3" 3" 4"
   Pump Skid, Inlet n/a 2"
DN50
2"
DN50
2"
DN50
3"
DN80
4"
DN100
4"
DN100
4"
DN100
6"
DN150
   Pump Skid, Outlet n/a 1"
DN25
1"
DN25
1"
DN25
2"
DN50
3"
DN80
3"
DN80
3"
DN80
3"
DN80
  

Blackmer Pumps
Selection Chart
  
60Hz 
All prices and specifications are
subject to change without notice.

Direct-Driven Belt-Driven
LGF1

AEP-
03B

LGF1P

AEP-
04B

LGL1.25

AEP-
08B

LGL1.5

AEP-
12B

LGL2

AEP-
18B

LGL3

AEP-
28B

LGL3

AEP-
37B

LGL4

AEP-
66B

LGL4

AEP-
85B

Single Pump System US-$
15,336
US-$
15,730
US-$
16,791
US-$
19,726
US-$
21,967
US-$
34,681
US-$
36,326
US-$
52,776
US-$
57,573
Duplex Pump System US-$
30,980
US-$
31,775
US-$
33,920
US-$
38,940
US-$
44,374
US-$
70,058
US-$
73,381
US-$
106,608
US-$
116,300

Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar discharge)

Find "your" LPG type and the sample operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than, the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number.

   HD-5 Propane
  
Min. Temperature   0F / -18C
   ΔP  78 psi / 5.4 bar
gph  168
kg/h  325
264
511
456
883
720
1394
1104
2137
1656
3206
2208
4274
3960
7666
5088
9850
   HD-5 Propane
  
Min. Temperature   -40F / -40C
   ΔP  99 psi / 6.8 bar
gph  144
kg/h  279
240
465
432
836
696
1347
1008
1951
1440
2788
1992
3856
3480
6737
4752
9199
   LPG with 50% Propane/50%Butane
  
Min. Temperature   32F / 0C
   ΔP  74 psi / 5.1 bar
gph  120
kg/h  246
192
394
288
591
456
936
744
1527
1128
2315
1440
2955
2640
5418
3336
6846
  LPG with 50% Propane/50%Butane
  
Min. Temperature   15F / -10C
   ΔP  82 psi / 5.7 bar
gph  120
kg/h  246
168
345
288
591
456
936
696
1428
1080
2216
1416
2906
2520
5171
3240
6649
  LPG with 30% Propane/70%Butane
  
Min. Temperature   32F / 0C
   ΔP  84 psi / 5.8 bar
gph    72
kg/h  151
120
252
192
404
312
656
480
1010
768
1616
960
2020
1752
3686
2232
4696
Electric Motor 220V 60Hz 220 or 460V 60Hz 460V 60Hz
   Motor Type Single-Phase

3-Phase
(all 3-phase motors require magnetic starters and overload protection)

   Motor Protection

Class I, Div 1, Group D  (Flame Proof)

   Motor Size [hp] 1 1.5 3 5 7.5 10 15 20 25
   Motor RPM 1750 1750 1750 1750 520 420 520 420 520
Pump Connections

All pump body connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100 and above).

   Pump Body, Inlet 1" 1" 1.25" 1.5" 2" 3" 3" 4" 4"
   Pump Body, Outlet 1" 1" 1.25" 1.5" 2" 3" 3" 4" 4"
   Pump Skid, Inlet 1.5"
DN40
1.5"
DN40
2"
DN50
2"
DN50
3"
DN80
4"
DN100
4"
DN100
6"
DN150
6"
DN150
   Pump Skid, Outlet 1"
DN25
1"
DN25
1"
DN25
1.5"
DN40
2"
DN50
3"
DN80
3"
DN80
4"
DN100
4"
DN100
   

Blackmer Pumps
Selection Chart
  
50Hz 
All prices and specifications are
subject to change without notice.

Direct-Driven Belt-Driven
LGF1

AEP-
03B

LGF1P

AEP-
04B

LGL1.25

AEP-
08B

LGL1.5

AEP-
12B

LGL2

AEP-
18B

LGL3

AEP-
28B

LGL3

AEP-
37B

LGL4

AEP-
66B

LGL4

AEP-
85B

Single Pump System US-$
16,020
US-$
16,415
US-$
17,478
US-$
120,047
US-$
22,624
US-$
35,470
US-$
37,354
US-$
54,489
US-$
59,117
Duplex Pump System US-$
32,363
US-$
33,161
US-$
35,306
US-$
40,497
US-$
45,760
US-$
71,649
US-$
75,459
US-$
110,071
US-$
119,853

Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar discharge)

Find "your" LPG type and the sample operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than, the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number.

   HD-5 Propane
  
Min. Temperature   0F / -18C
   ΔP  78 psi / 5.4 bar
gph  120
kg/h  232
192
372
384
743
576
1115
1104
2137
1656
3206
2208
4274
3960
7566
5088
9850
   HD-5 Propane
  
Min. Temperature   -40F / -40C
   ΔP  99 psi / 6.8 bar
gph    96
kg/h  186
168
325
336
650
552
1069
1008
1951
1440
2788
1992
3856
3480
6737
4752
9199
   LPG with 50% Propane/50%Butane
  
Min. Temperature   32F / 0C
   ΔP  74 psi / 5.1 bar
gph  120
kg/h  246
144
296
264
542
384
788
744
1527
1128
2315
1440
2955
2640
5418
3336
6846
  LPG with 50% Propane/50%Butane
  
Min. Temperature   15F / -10C
   ΔP  82 psi / 5.7 bar
gph  120
kg/h  246
144
296
240
493
360
739
696
1428
1080
2216
1416
2906
2520
5171
3240
6649
  LPG with 30% Propane/70%Butane
  
Min. Temperature   32F / 0C
   ΔP  84 psi / 5.8 bar
gph    72
kg/h  151
96
202
168
353
240
505
480
1010
768
1616
960
2020
1752
3686
2232
4696
Electric Motor 230V 50Hz 400/415V 50Hz
   Motor Type Single-Phase

3-Phase
(all 3-phase motors require magnetic starters and overload protection)

   Motor Protection

Class I, Div 1, Group D  (Flame Proof)

   Motor Size [hp] 1 1.5 3 5 7.5 10 15 20 25
   Motor RPM 1450 1450 1450 1450 420 350 420 350 420
Pump Connections

All pump body connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100 and above).

   Pump Body, Inlet 1" 1" 1.25" 1.5" 2" 3" 3" 4" 4"
   Pump Body, Outlet 1" 1" 1.25" 1.5" 2" 3" 3" 4" 4"
   Pump Skid, Inlet 1.5"
DN40
1.5"
DN40
2"
DN50
2"
DN50
3"
DN80
4"
DN100
4"
DN100
6"
DN150
6"
DN150
   Pump Skid, Outlet 1"
DN25
1"
DN25
1"
DN25
1.5"
DN40
2"
DN50
3"
DN80
3"
DN80
4"
DN100
4"
DN100
 

Motor Starters and Other Options for Single-Phase Pumps (fits both Blackmer and Corken Pumps)

Liquid Transfer Pumps with single-phase motors can be supplied with a simple, explosion-proof ON/OFF switch that is integrated into the junction box directly at the pump motor. If the pump control is desired to be integrated with the vaporizer- or vaporizer/blender control system (for example to facilitate remote monitoring and control), pumps with single-phase motors can also be equipped with contactors.
 
It is recommended that contactor-equipped pumps are also equipped with a local Start/Stop station that allows pump control from the pump location. AES Start/Stop stations are configured with an explosion-proof enclosure (Class I, Div 1, Group D [Flame-Proof]), green START button, red STOP button, and amber pilot light (pump ready to be started).
  
The operation of single-phase pumps with contactors can also be automated in response to the pressure in the storage tanks (pump will start automatically if tank pressure falls below an adjustable setpoint, and stays on until the tank pressure has recovered above a second adjustable setpoint).
 

Description (for Single-Phase Motors) Single-Pump Dual-Pump

Pump Contactor for single-phase pumps, max. motor size 5HP; installed in vaporizer- or vaporizer/blender control panel; terminals for AC feed, pump connection, and control voltage.

US-$ 837 US-$ 1,509

Pump Contactor for single-phase pumps, max. motor size 5HP; installed in separate enclosure; supplied loose for indoor field installation (NEMA 1).  

US-$ 1,173 US-$ 2,112

Pump Contactor for single-phase pumps, max. motor size 5HP; installed in separate enclosure; supplied loose for outdoor field installation (NEMA 3R).

US-$ 1,524 US-$ 2,464
Automatic Start/Stop Function and Control System Integration  (for Single-Phase Motors) Single-Pump Dual-Pump

Integration of pump control in vaporizer- or vaporizer/blender control system; includes Start/Stop Station, Explosion-Proof, NEMA 7,9,3R Outdoor Enclosure; Start/Stop Station; Pilot Light; installed at pump skid.

US-$ 2,904 US-$ 4,256
Automatic pump start/stop in response to pressure in storage tank(s); includes option "Integration of pump control in vaporizer- or vaporizer/blender control system"; includes Rosemount pressure transmitter in pump inlet. US-$ 6,081 US-$ 7,434
Start/Stop Stations (for Single-Phase Motors) Single-Pump Dual-Pump

Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

US-$ 1,689 US-$ 3,041

Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; and integrated ESD Station (Mushroom Button); supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

US-$ 2,066 US-$ 3,418
  

Motor Starters and Other Options for Three-Phase Pumps (fits both Blackmer and Corken Pumps)

Liquid Transfer Pumps with 3-phase motors always require magnetic motor starters. All AES magnetic motor starters are configured with contactor, solid state motor overload protection, service-disconnect function, and manual reset.

AES Starter Packages will be configured to match the selected pump size and motor, and are available for indoor installation, outdoor installation, and explosion-proof Class I, Div 1, Group D [Flame-Proof] installations. It is recommended that all pumps are also equipped with a local Start/Stop station that allows pump control from the pump location. AES Start/Stop stations are configured with an explosion-proof enclosure (Class I, Div 1, Group D [Flame-Proof]), green START button, red STOP button, and amber pilot light (pump ready to be started).

All types can also be integrated into the vaporizer or vaporizer/blender control system for remote monitoring and control of the pump operation.

The pump operation can also be automated in response to the pressure in the storage tanks (pump will start automatically if tank pressure falls below an adjustable setpoint, and stays on until the tank pressure has recovered above a second adjustable setpoint).

Starter Packages Description (for Three-Phase Motors)

Single-Pump Dual-Pump

Starter Package, Non-Explosion-Proof; installed in separate enclosure without Start/Stop Station; supplied loose for indoor field installation (NEMA 1 Indoor Enclosure).

up to
10 HP
US-$ 2,096 US-$ 3,773
over
10 HP
US-$ 2,514 US-$ 4,526

Starter Package, Non-Explosion-Proof; installed in separate enclosure with integrated Start/Stop Station and Pilot Light; supplied loose for indoor field installation (NEMA 1 Indoor Enclosure).

up to
10 HP
US-$ 2,535 US-$ 4,212
over
10 HP
US-$ 2,954 US-$ 4,966

Starter Package, Non-Explosion-Proof; installed in separate enclosure without Start/Stop Station; supplied loose for outdoor field installation (NEMA 3R Outdoor Enclosure).

up to
10 HP
US-$ 2,295 US-$ 3,972
over
10 HP
US-$ 2,713 US-$ 4,725

Starter Package, Non-Explosion-Proof; installed in separate enclosure with integrated Start/Stop Station and Pilot Light; supplied loose for outdoor field installation (NEMA 3R Outdoor Enclosure).

up to
10 HP
US-$ 2,734 US-$ 4,411
over
10 HP
US-$ 3,153 US-$ 5,164

Starter Package, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure with integrated Start/Stop Station and Pilot Light; supplied loose for outdoor field installation (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

up to
10 HP
US-$ 5,023 US-$ 9,042
over
10 HP
US-$ 5,874 US-$ 10,560

Automatic Start/Stop Function and Control System Integration (for Three-Phase Motors)

Single-Pump Dual-Pump
Integration of pump control in vaporizer- or vaporizer/blender control system; includes Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; green START button; red STOP button; amber Pilot Light; installed in separate enclosure at pump skid. US-$ 2,904 US-$ 4,256

Automatic pump start/stop in response to pressure in storage tank(s); includes option "Integration of pump control in vaporizer- or vaporizer/blender control system"; includes Rosemount pressure transmitter in pump inlet.  

US-$ 6,081 US-$ 7,434

Start/Stop Stations (for Three-Phase Motors)

Single-Pump Dual-Pump
Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure). US-$ 1,689 US-$ 3,041
Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; and integrated ESD Station ("Mushroom" Button); supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure). US-$ 2,066 US-$ 3,418

Starter Installation (for Three-Phase Motors)

Single-Pump Dual-Pump
Installation of Non-Explosion-Proof Motor Starter inside a Vaporizer Control Room; includes separate conduit entries in walls of vaporizer control room for power feed, connection to pump, and connection to Start/Stop Station. US-$ 1,005 US-$ 1,810
Installation of Non-Explosion-Proof Motor Starter in a separate enclosure outside a Vaporizer Control Room; includes separate conduit entries for power feed, connection to pump, and connection to Start/Stop Station. US-$ 1,786 US-$ 3,214
Installation of Explosion-Proof Motor Starter at pump skid; includes mounting frame for ex-proof starter enclosure; includes conduit connection between starter enclosure and motor junction box; includes 18-inch flex conduit. US-$ 2,558 US-$ 4,606
Last Update 31Jan16

HOME | PRODUCTS | VAPORIZERS | MIXERS/BLENDERS | PACKAGED SYSTEMS | ACCESSORIES | PRODUCT APPROVALS | PRICE LISTS
DOWNLOADS | TECHNOLOGY | LPG PROPERTIES | SYSTEM SIZING WORKSHEET | NEWS | AES COMPANY PROFILE | AES LOCATION
AES CONTACTS | LITERATURE REQUEST | SEARCH | SITE MAP GraviBlend-3 GRAVITOMETER OTHER BLENDING APPLICATIONS